Specifications of Digital Counters |
Model | C-500 | C-700 |
Displayed digits |
| Selection of 10μm |
| Selection of 1μm | Display |
| -9999.99 -- 00.00 -- 9999.99 | -999.999 -- 0.000 -- 999.999 | High-luminance LED display with 7 segments (red) |
|
Power supply voltage & power consumption |
| AC100V -- AC240V / 9VA or lower |
Operating temperature |
| 0 -- +40oC |
Compatible Linear Gauges |
| Selection of 10μm display |
| Selection of 1μm display |
| DL-2, D-5, D-10, D-20, D-30, D-50, D-100, DN-10, DN-20, D-5UZ | DL-2S, D-5S, D-10S, D-20S, D-30S, D-50S, D-100S DN-10S, DN-20S |
|
Accessories |
| AC power cord (2m) ; One cord | Metal fittings for panel installation ; Two units |
| ( to be used for installation in panel and securing stand fittings ) | Stand fittings ; One unit |
| ( to be used when counter is used as desktop device ) |
|
Terminal block functions ( Rear panel ) |
| Terminal block | --> Screwless terminal block | Usable electric cables | --> AWG22 - 28 | Length of peeled wire of cables | --> 8 - 9mm |
Pin alignment | (*1) | St/Sp | Controls "START" and "STOP" of MAX, MIN, P-P measurement mode. | (*2) | React | Controls "SUSPEND" and "START" of P-P measurement mode. | 3 | Latch | Controls "LATCH" and "CANCEL" of measured value. | 4 | Reset | External "RESET" "PRESET" ( Function available only in Model No. C-700 ) | 5 | Alarm | Error signal output |
| Max Display | Min Display | P-P Display | (*6) | -NG | Outputs -NG based on OK±NG judgment (red LED). | --> | +NG(2) | -NG(1) | NG(2) | (*7) | OK | Outputs OK based on OK±NG judgment (green LED). | --> | OK | OK | OK | (*8) | +NG | Outputs +NG based on OK±NG judgment (orange LED). | --> | +NG(1) | -NG(2) | NG(1) |
| (1) : NG output in first stage (2) : NG output in second stage | 9 | GND | GND | (* ) | Circled numbers indicate functions available only in Model No. C-700 |
|
Dip sw setting functions ( Printed circuit board ) |
| Dip(1) |
| Dip(2) | SW 1 | Select 1μm or 10μm |
| SW 1 | Settings by Manufacturer | SW 2 | Select direction of counting. |
| SW 2 | Select whether or not to include default values for OK±NG judgment. | SW 3 | Select activation or non- activation of error output. |
| SW 3 | Select either "orthogonal" or "sine" for input waveform. | SW 4 | Select activation or non- activation of overflow. |
| SW 4 | Select either 400msec or 100msec for RESET time. |
|
Data output (RS-232C) D-Sub9P plug INCH screw |
|
Options |
| Excel input software |
| BCD output board |
| Pin Alignment | 1 | NC | -- |
| Communication mode ; Half-duplexasynchronouscommunication | 2 | Rxd | in <-- |
| Communication speed ; 9600bps | 3 | Txd | --> out |
| Format ; 7Bit ASCI I | 4 | NC | -- |
| Parity ; even number | 5 | SG | -- |
| Stop bit ; 1Bit | 6 | NC | -- |
| RTS / CTS ; Returned when not in use. | 7 | RTS | --> out |
| Reception command ; Transmission request ASCI I [T] [t] | 8 | CTS | in <-- |
| ; Reset ASCI I [R] [r] |
| 9 | NC | -- |
| Connection cables ; Cross cables ( not included ) |
PK-2002 |
| ; Data imported into Excel cells from RS-232C output. | CB-BCD |
| ; Cannot be used in combination with RS-232C output. |
|
Display functions |
| 1/1 display | --> Displays the measured value as is. | 1/2 display | --> Displays the measured value after halving it. | ×2 display | --> Displays the measured value after doubling it. | Note ; With 1μm display and ×2 display, the lowest digit will be displayed as an even number. |
Presetting display function |
| Zero setting only |
| Can display preset values |
|
Measurement mode function [MAX] [MIN] [P-P] |
| --- | Current value display | Maximum value (Max) | RESET action is taken by ST of the ST/SP control terminal. | Minimum value (Min) | Deflection (P-P) |
|
OK±NG judgment function ( Refer to terminal output circuit ) |
| --- | Current value mode | +NG | OK | -NG | Maximum value mode | OK | +NG (1) | +NG (2) | Minimum value mode | OK | -NG (1) | -NG (2) | Deflection mode | OK | NG (1) | NG (2) |
|
Dimensions | / | Weight |
| 144(W)×72(H)×160(D)mm | / | 950g |
|